Professional drill bit with medium grit diamond coating for perfect cuticle treatment. Extremely durable, abrasion-resistant coating guarantees extended use of the drill bit.

The flame-shaped drill bit is designed to clean the nail plate of unwanted epithelium, lift cuticles and create a clean surface under the nail folds, facilitating precise painting near the cuticles. Perfect for combination manicure and pedicure.


Intended for disinfection and sterilisation in a cosmetic autoclave.

Benefits of using the flame-shaped drill bit:

  • Excellent for cuticles and epithelia treatment
  • Extended lifetime of the drill bit due to abrasion-resistant coating
  • The new flame shape facilitates precise cuticles removal from the nail plate
  • Perfect for combination manicure and pedicure
  • Intended for disinfection and sterilisation in a cosmetic autoclave

Please read 'more information' tab

8,00 € tax incl.

  • IMPORTANT! When disinfecting, strictly follow the preparation instructions for the selected preparation! Failure to follow the rules of correct preparation, exposure time, temperature and concentration may cause corrosion and loss of nail drill bit properties. Tools that are rusty or showing signs of corrosion, you have to fully remove the rust before disinfecting.

    After the disinfection procedure, it is necessary to rinse the instruments with clean water to remove any residual disinfectant solution. After rinsing, the instruments must be fully dried, e.g. with a dust-free towel, and then the moving parts should be lubricated with medical paraffin. Metal tools are suitable for high-temperature sterilization in a Type B autoclave.

    Instruments should be sterilized in a sterile barrier (paper-foil bags or sleeves) to maintain sterility after sterilization and to keep them safe. The tools should be sterilized only in perfect working autoclaves with a valid inspection and only with the use of demineralized or distilled water of the purity specified by the autoclave manufacturer. The use of poor quality water may cause corrosion and damage the tool.

    We do not recommend the use of ball sterilizers. This can cause mechanical damage and the lack of sterility of the tools. Improper cleaning or disinfection of instruments after use, or the omission of one of the steps, significantly reduces the effectiveness of sterilization and can cause corrosion.

    It is important to:

    ● Use personal protective equipment (headgear, mask, long rubber gloves, waterproof apron);

    ● Do not use brass / copper brushes or metal cleaning sponges etc.

    ● Do not use alcohol-based solutions

    ● The temperature of the disinfecting solution should not exceed 40C

    ● Do not use chlorinated water to prepare a disinfectant solution or to rinse instruments

    The Semilac brand is not responsible for damage to the tools as a result of non-compliance with the rules of disinfection and sterilization. The corrosion resistance of steel is maintained by the tools only when all the rules and instructions are followed, as well as with the use of high-quality and certified cleaning and disinfection agents. The instructions and procedures attached to the disinfectants and sterilizing devices must be strictly followed.